HERMetic UTImeter Otex 25m portable level gauging equipment
- TS MOUTI_PLSTD15BA - HERMetic UTImeter Otex 15m
- TS MOUTI_PLSTD25BA - HERMetic UTImeter Otex 25m
- TS MOUTI_PLSTD35BA - HERMetic UTImeter Otex 35m
- TS MOUTICPLSTD15BA - HERMetic UTImeter Otex Chem 15m
- TS MOUTI_PLSTD25BA - HERMetic UTImeter Otex Chem 25M
- TS MOUTICPLSTD35BA - HERMetic UTImeter Otex Chem 35m
- TS MOUTICPLVIS15BA - HERMetic UTImeter Otex Chem Visc 15m
- TS MOUTICPLVIS25BA - HERMetic UTImeter Otex Chem Visc 25m
- TS MOUTICPLVIS35BA - HERMetic UTImeter Otex Chem Visc 35m
- TS MOUTICPLFRE15BA - HERMetic UTImeter Otex FR Plate Chem 15m
- TS MOUTICPLFRE25BA - HERMetic UTImeter Otex FR Plate Chem 25m
- TS MOUTICPLFRE35BA - HERMetic UTImeter Otex FR Plate Chem 35m
- TS MOUTI_FRVIS15BA - HERMetic UTImeter Otex FR plate Visc 15m
- TS MOUTI_FRVIS25BA - HERMetic UTImeter Otex FR plate Visc 25m
- TS MOUTI_PLFRE15BA - HERMetic UTImeter Otex French plate 15m
- TS MOUTI_PLFRE25BA - HERMetic UTImeter Otex French plate 25m
- TS MOUTI_PLFRE35BA - HERMetic UTImeter Otex French plate 35m
- TS MOUTI_PLVIS15BA - HERMetic UTImeter Otex Visc 15m
- TS MOUTI_PLVIS25BA - HERMetic UTImeter Otex Visc 25m
- TS MOUTI_PLVIS35BA - HERMetic UTImeter Otex Visc 35m
HERMetic UTImeter Otex 25m
Part Number:TS MOUTI_PLSTD25BA
Tape 25m
The HERMetic UTImeter Otex is a portable liquid level gauge designed to be operated under open conditions on petroleum and chemical storage tanks where open gauging is permitted. The unit is used for custody transfer, inventory control measurement and free water detection on shore tanks. The HERMetic UTImeter Otex is set on the open gauging hatch.
The unit enables 3, optionally 4 measurements in one single operation:
• Ullage
• Temperature
• Oil-Water interface level
• Innage, Reference height (Visc version)
All HERMetic UTImeters are now equipped with the sensor “ ULTRA “ for use in low and high viscous liquids.The ULTRA sensing probe consists of a stainless steel tube terminated by a PEEK head. The sensing probe includes an ultrasonic liquid level sensor, a temperature sensor and a conductivity electrode. The sensitivity for ullage and interface measurement does not require any adjustment. The sensor is calibrated once at the factory and does not require subsequent calibration. The temperature transducer is a RTD element. The characteristics of the RTD element are stored inside the sensor. The sensor is sending true temperature values to the electronic box and display.
Low maintenance costs:
Fully modular unit. Change tape, sensor or instrument unit yourself.Easy and detailed instructions in Operation and Service Manual.
Benefits
• 100% repeatability of measures.• No adjustment of the sensitivity required.
• Small diameter.
• Chemically resistant to corrosive liquids (Chem version).
• High mechanical stability.
• No degradation of the sensitivity due to ageing of the sensor.
Technical specifications:
Accuracy of ullage-interface detection: ± 2 mm (± 0.08” approx.)
Ullage, interface indication: Audible and Visible selectable
Tape length: 15 m/50 ft, 30 m/100 ft, 35 m/115 ft
Tape graduation: Metric/English
Tape resolution: 1 mm / 1/16”
Tape accuracy: ± 1.5 mm/30 m (±1/16”/100 ft approx.)
Meets API MPMS Chap 3.1A and ISO 4512 requirements
Temperature accuracy: ± 0.1°C (0°C to 70°C);
Meets API MPMS Chap 7 request
Meets ISO 4268 , IP PMM Part IV
± 0.2°F (32°F to 158°F)
Ambient temperature range: -20°C to 50°C / (-4°F to 122°F)
Temperature sensor measurement range: -40°C to 90°C / (-40°F to 194°F)
Temperature measurement resolution: 0.01° or 0.1° selectable
Temperature reading: °C or °F selectable
LCD Display: 8 characters with backlight
Power: Approved 9V batteries
Weight with 15 meter / 50ft tape: 3.5 kg / 7.7 Lbs.
Hazardous environments approvals
ATEX II 1 G EEx ia IIB T4 / Tamb 50°C
Factory Mutual
CL I, DIV 1, C&D, T4 Tamb 50°C and
CL I, ZN 0, AEx ia IIB T4 Tamb 50°C
China: CQST ExiaIIBT4
IECEx: Zone 0 Ex ia IIB T4 / Tamb 50°C